Skip to main content

GTI Industrial Dryers

Short answer: A dryer energy audit measures how much energy your dryer uses for each kilogram of water it removes, then splits that energy into the useful part (evaporating water) and the losses (hot exhaust, heating the product, heat lost through the dryer body, and losses in the steam or heater system). You need four sets of numbers taken during steady operation: feed rate and moisture, product rate and moisture, fuel or steam use, and air temperatures and humidity at inlet and exhaust. With those, you can calculate specific energy consumption, compare it with the theoretical minimum and see which loss is worth fixing first.

This guide is for plant engineers, energy managers and production heads who want a defensible baseline before spending money on dryer upgrades, heat recovery or a new dryer.

Why measure before you fix

Drying is energy-hungry. Ian Kemp’s chapter Fundamentals of Energy Analysis of Dryers notes that drying accounts for 10–20% of total industrial energy use in most developed countries. Without a baseline, it is impossible to tell whether a proposed improvement is worthwhile or to prove afterwards that it worked. Our earlier article on reducing dryer energy consumption lists the improvement levers. This article covers the step before that: measuring where the energy goes.

The key indicator: specific energy consumption

Specific energy consumption (SEC) is the energy supplied to the dryer divided by the mass of water evaporated, in kJ per kg of water (or kcal/kg, or kWh/kg). CanmetENERGY’s paper on the energy performance of convective dryers (Kudra, Natural Resources Canada) uses SEC to compare real industrial dryers with a theoretical adiabatic dryer working at the same exhaust conditions. The difference, which it calls excess specific energy consumption, shows how far a dryer is from what its operating conditions would allow.

Kemp gives the reference point: the latent heat of evaporation of water is 2,501 kJ/kg at 0°C and 2,256 kJ/kg at 100°C, and about 2,400 kJ/kg is a good working figure near ambient temperature. Every real dryer uses more than this per kg of water, because of the losses described below. Report thermal energy and electrical energy separately. Fan and drive power are real costs, but a kWh of electricity and a kWh of fuel heat are not the same thing.

Step 1: Define the boundary and the operating point

  • Boundary: decide what is inside the audit. The dryer alone? The dryer plus its air heater? The boiler and steam lines as well? Kemp separates thermal inefficiencies inside the dryer from inefficiencies in the utility system, such as boiler efficiency, steam leaks and distribution losses. Keep the two apart.
  • Operating point: audit during steady, representative production. Start-up, shutdown and low-load running use more energy per kg of water, and Kemp lists them as a separate loss category. Record them separately if they are frequent.
  • Duration: long enough to average out normal fluctuations. Several hours of steady operation is a reasonable minimum for continuous dryers. For batch dryers, cover complete batches.

Step 2: Measure the mass balance

MeasurementHowWhy
Wet feed rateWeigh-feeder, belt scale or timed batch weightsBasis for water load
Feed moistureLaboratory samples at regular intervals, stating wet or dry basisWater entering
Product rateWeigh packed or discharged product over the same periodCross-check on feed rate
Product moistureLaboratory samples, same method as feedWater leaving with product
Fines in exhaustCyclone or bag filter catchCloses the solids balance

Water evaporated = water in feed − water in product. Check that dry solids in equal dry solids out, allowing for fines. If the solids balance does not close within a few per cent, find out why before calculating anything else. Our guide to calculating evaporation load shows the wet-basis and dry-basis formulas.

Step 3: Measure the energy supplied

  • Steam-heated dryers: measure steam flow with a meter, or collect and weigh condensate over a timed period. Record steam pressure, so the energy per kg of steam can be taken from steam tables. Check that traps are working, because blowing traps inflate steam use.
  • Thermic fluid: measure fluid flow and the supply and return temperatures across the dryer’s heater.
  • Direct-fired or hot air generator: measure fuel use (by flow meter, tank dip or weighing biomass) and use a measured or supplier-certified calorific value. India’s Bureau of Energy Efficiency guide book chapter on fuels and combustion explains fuel properties and calorific value.
  • Electricity: log fan, drive, conveyor and any heater power with an energy meter.

For steam systems, the US Department of Energy tip sheet on benchmarking the fuel cost of steam explains how boiler efficiency and fuel price translate into the cost of each kg of steam.

Step 4: Measure air conditions

For convective (hot-air) dryers, measure inlet air temperature, exhaust air temperature and exhaust humidity, plus ambient temperature and humidity. If you can measure air flow, do so; otherwise, the air flow can be estimated from the water evaporated and the rise in air humidity between inlet and exhaust. This calculation also checks the mass balance.

Step 5: Calculate and split the losses

Kemp’s heat balance for a continuous convective dryer says that the heat given up by the hot air equals the evaporation load plus the sensible heating of the solids plus heat losses from the dryer. In practice, the energy supplied divides into:

Energy itemWhat it representsWhere it shows up
EvaporationLatent heat to turn water into vapourUseful work
Exhaust lossHeat leaving in the exhaust air above ambientUsually the largest loss in hot-air dryers
Product sensible heatHeating the dried solids and residual waterProduct leaving warm
Body lossesRadiation and convection from casing, ducts and leaksHot surfaces, air leaks
Utility lossesBoiler, heater and distribution inefficiencyOutside the dryer body
ElectricalFans, drives, conveyorsSeparate meter

Kemp’s worked example shows how these add up. For a convective dryer with inlet air at 150°C, exhaust air at the adiabatic saturation temperature would give a dryer efficiency of about 80% (latent heat divided by heat supplied to the air). When the exhaust is kept 25°C above its dew point, as most real dryers are, efficiency falls to just over 60%. Heating the solids by 30°C in the falling-rate period pushes it down to about 54%. Those figures belong to Kemp’s example, not to your dryer, but they show why exhaust temperature and humidity are usually the first things to look at.

Step 6: Compare and prioritise

Once you have the split, the priorities usually follow:

  1. High exhaust temperature or low exhaust humidity: the dryer is moving more air than the evaporation needs, or the exhaust is leaving with unused drying capacity. Check air flow settings, recirculation and control.
  2. Final moisture well below specification: over-drying wastes energy and capacity. Tighten moisture control.
  3. Large body losses: check insulation, door seals, duct joints and air in-leakage.
  4. Utility losses: check boiler efficiency, steam traps, condensate return and insulation on steam lines.
  5. Feed moisture higher than necessary: mechanical dewatering upstream is normally far cheaper per kg of water removed than thermal drying.
  6. Heat recovery: only after the above, consider exhaust heat recovery, because recovering heat from a dryer that is wasting air is less effective than correcting the air flow first.

A simple audit record

Keep each audit in a consistent format so that results can be compared over time:

  • Date, product grade and production rate
  • Feed and product moisture (basis stated) and water evaporated, kg/h
  • Thermal energy supplied, kW, and SEC, kJ/kg water
  • Electrical energy, kW, and kWh per kg water
  • Inlet, exhaust and ambient air temperature and humidity
  • Main losses identified and actions agreed

Repeat it after any change, and at regular intervals, because fouled heat exchangers, worn seals and drifting controls raise SEC over time. Regular mechanical maintenance helps keep the numbers stable; our rotary dryer maintenance checklist is one example.

When the audit points to a new dryer

Sometimes the audit shows that the existing dryer cannot reach a sensible SEC for the product: for example, a hot-air dryer handling a pasty feed that would suit indirect drying, or a high-temperature dryer used for a product that dries well at low temperature. In those cases, the audit data becomes the specification for the replacement. GTI offers rotary drum dryers, continuous band dryers, industrial spray dryers and indirect paddle dryers, among other designs, and the right choice depends on the material, not the energy figure alone. If the heat source itself is in question, see our guide to choosing between steam, thermic fluid, gas and biomass.

Frequently asked questions

What is a good specific energy consumption for a dryer?

There is no single good figure, because SEC depends on the product, the moisture removed, the dryer type and the air conditions. The theoretical floor is the latent heat of water, about 2,400 kJ/kg near ambient. Compare your dryer with its own past results and with the theoretical value at its operating conditions.

Can I audit a dryer without an air flow meter?

Yes. Air flow can be estimated from the water evaporated and the change in air humidity between inlet and exhaust. A direct measurement is still useful as a cross-check.

How often should a dryer energy audit be done?

After any significant change to the dryer, product or heat source, and periodically otherwise, so that slow deterioration is caught early.

Should electrical energy be added to thermal energy?

Report them separately. Combining them hides important differences in cost and source.

Get help interpreting your dryer audit

For assistance with dryer energy assessment, dryer selection or a project-specific quotation, contact Genex Tech Industries LLP (GTI Group).

Email: mktg@gtidryers.com
Call or WhatsApp: +91-93300 77417
Website: https://gtidryers.com/

Please share your material, required wet-feed capacity, initial and target moisture, available heating source and installation location.

Chat on WhatsApp